System water

System cleaning, inhibitor and filters

The water inside a heating system is easy to forget, yet a new boiler is connected to it on the day it is fitted. This page explains what England's rules expect to happen to that water before and after a new boiler goes in, and how you can tell it was done.

Last reviewed · facts read at source on 3 November 2026 · published by SEO-DONS LTD · sources

Why it matters

What collects inside an older system

Over the years the water in a wet heating system gathers sludge from corrosion inside the radiators and pipes, and in hard water areas it can leave scale behind. Connect a new boiler to that water as it is, and the debris can be carried straight into the new boiler's heat exchanger.

That is why England's guidance puts the cleaning first. Paragraph 8.8 of Approved Document L (2021 edition, with 2023 amendments) says that before a new heating appliance is installed, the circuits should be thoroughly cleaned and flushed, and that a suitable chemical inhibitor should be added.

Hard water

Scale and hard water areas

Hard water carries dissolved minerals that turn into limescale when the water is heated. For a combi, which heats mains water as it flows through, that matters on the hot water side. Paragraph 8.8 asks for the feed water to a combi's hot water circuit to be treated against scale in hard water areas, and the Approved Document's glossary counts an area as hard where total hardness is above 200 ppm, measured as calcium carbonate.

Your water supplier can tell you the hardness of your supply. If it is above that line and a combi is being fitted, the quote should say what scale treatment is included.

Step by step

What should happen to the system water

Water treatment steps for a new boiler in England. Sources: Approved Document L, Volume 1, 2021 edition with 2023 amendments (paragraph 8.8 and the glossary), the Energy Saving Trust and Benchmark; read 3 November 2026.
StepWhat it involvesWhere it comes from
Clean and flushThe heating circuits are thoroughly cleaned and flushed before the new appliance goes inApproved Document L, 8.8
InhibitorA suitable chemical inhibitor is added to the system waterApproved Document L, 8.8
Scale treatmentIn hard water areas (total hardness above 200 ppm as calcium carbonate), the water feeding a combi’s hot water circuit is treated against scaleApproved Document L, 8.8 and glossary
Preparation and commissioningThe system is prepared and commissioned to BS 7593Approved Document L, 8.8
A record of commissioningThe Benchmark Commissioning Checklist can be used to show commissioning was doneApproved Document L, 8.8; Benchmark
Magnetic filterEncouraged by building regulations, according to the Energy Saving Trust; the replacing installer should fit one if there is noneEnergy Saving Trust

"Flush" on a quote can mean several things

A quote that simply says "system flush" does not tell you how the work will be done. Ask which method will be used, whether a cleaning chemical goes in, which inhibitor is added afterwards, and whether a filter is being fitted or an existing one cleaned.

Power flushing

Do you need a power flush?

A power flush is one way of cleaning a system: a pump is connected to the heating circuit and water, usually with a cleaning chemical, is driven round at high flow to shift sludge. Other methods circulate a chemical cleaner with the system's own pump and then flush it out, or flush the circuit using mains water pressure.

What England's guidance asks for is a thorough clean and flush of the circuits before the new boiler goes in. Which method suits a given system depends on its age and condition, what it is made of and anything the boiler's manufacturer requires, and that choice is for the installer to explain in the quote. If one firm prices a power flush and another a chemical clean, ask each why its method suits your system.

Whichever method is used, the end point should be the same: clean circuits, the right inhibitor, and a system prepared and commissioned to BS 7593, the British Standard code of practice for this work.

Filters

Magnetic filters

A magnetic filter sits on the heating circuit and catches the iron-rich sludge that corrosion produces, holding it where it can be cleaned out at a service instead of letting it collect in the boiler. The Energy Saving Trust says building regulations encourage magnetic filters, and that the installer replacing a boiler should fit one if the system does not already have one.

If there is a filter already, ask for it to be checked and cleaned during the job, and make sure the quote says which it is: a new filter, or the existing one kept.

Proof it was done

Commissioning and the Benchmark checklist

Cleaning, inhibitor and commissioning belong together, and the paperwork should show all three. Approved Document L notes that the Benchmark Commissioning Checklist can be used to show commissioning was done. The Benchmark scheme, launched in 1999, describes completing its checklist as a way of meeting the commissioning requirements in Part L, and the checklist is now available in digital form as well.

Ask for the completed checklist before you make the final payment, and for a note of which inhibitor went in. The new boiler installation page covers the rest of the day itself, and comparing heating quotes shows where these lines belong on a quote.

Planning more than a boiler swap? If radiators or pipework are being replaced as well, radiators and flow temperature explains how they are sized, and boiler types covers what changes when you move to or from a combi. To have the cleaning priced as part of the job, get a heating quote.

Questions about cleaning and water treatment

Do I need a power flush?

Not necessarily. England’s rules require the heating circuits to be thoroughly cleaned and flushed before a new boiler is fitted, but a power flush is only one way of doing that. Which method suits your system is for the installer to explain in the quote, so ask each firm why it has chosen its method.

What does an inhibitor do?

It is a chemical added to the water in a heating system to protect the boiler, pipes and radiators from corrosion and scale. Approved Document L asks for a suitable inhibitor to be added when a new boiler is installed.

How can I tell the system was actually cleaned?

Ask for the paperwork. England’s guidance names the completed Benchmark checklist as one way to show commissioning was done, so ask for it at handover, along with a written note of the cleaning method and the inhibitor used, and keep both with the boiler’s manual.

My system already has a magnetic filter. Does the installer need to fit another?

Not if the existing one is working. The Energy Saving Trust’s point is that the replacing installer should fit a magnetic filter where there is none, so with one already in place the sensible step is to have it checked and cleaned during the job, and the quote should say so.

What if a quote does not mention cleaning at all?

Ask about it before you sign. Approved Document L expects the circuits to be thoroughly cleaned and flushed, and an inhibitor added, before a new heating appliance goes in, so a quote that says nothing may simply have left the line out or may not include the work. Either way, get the method and the inhibitor written into the quote.

Where this page's facts come from

Get a heating quote that covers the system water

Tell us which boiler you have now, roughly how old the radiators and pipes are, and whether there is a magnetic filter, so the quote can cover the cleaning as well as the boiler. We reply by email.

What happens next

  1. Your details go to SEO-DONS LTD, the company behind Heating and Boiler Installation.
  2. We read what you have sent about the house and its heating, and reply by email.
  3. Asking for a quote costs nothing and leaves you free to say no.
Add more about the house and its heating (optional)

Published by SEO Dons Ltd. We don't install boilers ourselves. We reply by email. See our privacy notice.

Get a heating quote
Get a heating quote