Hot water cylinders
Hot water cylinders: vented, unvented and heat-pump ready
In a home with a system or regular boiler, the hot water lives in a cylinder, and replacing the boiler is often the right moment to look at the cylinder too. This page covers the two kinds of cylinder, the rules in England when one is fitted or replaced, and why the cylinder matters if a heat pump might follow.
Last reviewed · facts read at source on 3 November 2026 · published by SEO-DONS LTD · sources
Two kinds
Vented and unvented: the difference
A vented cylinder is the older arrangement. Cold water reaches it from a storage tank higher up, usually in the loft, and the pressure at the hot taps comes from the height of that tank. It is a simple design, and it is the one that usually goes with a regular boiler and its loft tanks.
An unvented cylinder is sealed and filled straight from the mains, so hot water reaches the taps at close to mains pressure and no cold water tank is needed in the loft. Because it stores hot water under pressure, it carries safety devices that a vented cylinder does without, and in England fitting one is notifiable building work.
Which one you have
How to tell what is in the cupboard
Start in the loft. A cold water tank with a pipe running down to the cylinder means it is vented. An unvented cylinder has no loft tank feeding it, and it usually has a cluster of valves around it, often with a small expansion vessel and a discharge pipe leading away from it.
Some homes have no cylinder at all because the boiler is a combi. If that is you and you are thinking about stored hot water for the first time, the boiler types page explains what a system boiler and cylinder would change.
The rules
What applies when a cylinder is part of the job
| Situation | What applies | Where it comes from |
|---|---|---|
| An unvented cylinder is installed | Notifiable building work. The installer shows competence through registration with a competent person scheme for this work, or a current registered operative skills card for unvented systems | Approved Document G, 3.40 to 3.42 |
| A scheme-registered installer fits it | They self-certify the work, and the owner receives a compliance certificate, usually issued by the scheme operator | Approved Document G, 3.40 to 3.42 |
| Any cylinder is replaced | Electronic temperature control, such as a cylinder thermostat | Approved Document L, 5.26 |
| The boiler heating a cylinder is replaced | Separate time control for heating and hot water, unless one controller already does both | Approved Document L, 5.24 |
| The cylinder comes out for a combi | Most heat pumps work with a cylinder, so a later heat pump may mean fitting one again | Energy Saving Trust |
Check what the registration covers
GOV.UK keeps the list of authorised competent person schemes. For a heating or hot water system or its controls it names APHC, BESCA, Blue Flame Certification, Gas Safe Register, Certsure, HETAS, NAPIT and OFTEC. For an unvented cylinder, membership alone is not the whole answer: the registration has to cover that work, so ask which scheme the installer belongs to and whether it includes unvented systems.
Unvented work
Who can fit an unvented cylinder, and the certificate you get
England's Approved Document G treats installing an unvented hot water system as notifiable work, so building control has to be told about it. An installer can show they are competent to do it in one of two ways: registration with a competent person scheme for this kind of work, or a current registered operative skills card for unvented systems.
When the installer is registered with a scheme for the work, they can certify it themselves, and you as the owner receive a compliance certificate, usually issued by the scheme operator rather than by the installer. If the installer is not in a scheme for unvented work, ask before the job starts how it will be notified. Either way, file the certificate with the boiler's papers, because the Energy Saving Trust's advice is to keep building regulations documents for the day you sell.
When a cylinder is fitted alongside a new boiler, it should appear on the quote as its own line, giving the type, the size, the thermostat and who signs it off. The checklist on comparing heating quotes adds those lines when you tick a cylinder.
Controls
A cylinder brings its own controls
Stored water should be heated only as far as it needs to be, and only when it is wanted, and two of England's control rules follow from that. A new cylinder should have electronic temperature control, a cylinder thermostat being the example the guidance gives (paragraph 5.26 of Approved Document L). And when the boiler that heats a cylinder is changed, heating and hot water should run on separate timing unless one controller already handles both (paragraph 5.24).
The heating controls page sets these beside the controls every new boiler needs, including the extra rule that applies only to combis.
Heat-pump ready
Thinking about a heat pump
The Energy Saving Trust notes that most heat pumps work with a hot water cylinder. That gives the cylinder cupboard a value beyond the boiler you are buying now: take it out to fit a combi, and a later move to a heat pump may mean putting a cylinder back.
Treat "heat-pump ready" on a cylinder as a question rather than a promise. If you are replacing a cylinder now and a heat pump is a real prospect, ask the installer to confirm in writing that the cylinder quoted is designed to work with one. The boiler or heat pump page weighs up the bigger decision, and when you are ready you can get a heating quote for the cylinder on its own or with a new boiler.
Questions about hot water cylinders
Who can fit an unvented cylinder?
In England, an installer who can show competence for unvented systems, either through registration with a competent person scheme for that work or with a current registered operative skills card for unvented systems. Installing one is notifiable building work, and where a scheme-registered installer does it, the owner receives a compliance certificate, usually from the scheme operator.
Does a new cylinder need a thermostat?
Yes. When a cylinder is replaced in England, Approved Document L asks for electronic temperature control, and a cylinder thermostat is the example it gives. It stops the stored water being heated further once it reaches the set temperature.
Should I keep my cylinder if a heat pump is possible later?
It is worth weighing up before you decide. The Energy Saving Trust says most heat pumps work with a hot water cylinder, so swapping yours for a combi now could mean fitting a cylinder again later. Whether the cylinder you have would suit a heat pump is a separate question for whoever designs that system.
Does a vented cylinder need a tank in the loft?
Yes. A vented cylinder is fed from a cold water storage tank above it, which is usually in the loft. An unvented cylinder is filled from the mains, so it needs no such tank.
Does the cylinder have to be replaced when the boiler is?
No rule quoted on this page requires it. If the cylinder stays, the boiler replacement still brings the rule on separate timing for heating and hot water; if the cylinder is replaced, the new one needs its own thermostat. Whether the old cylinder is worth keeping depends on its age and condition, so ask the installer to give a reason either way.
Where this page's facts come from
- GOV.UK — Approved Document G, with 2024 amendments (PDF) read 3 November 2026
- GOV.UK — competent person schemes: current schemes read 3 November 2026
- GOV.UK — Approved Document L, Volume 1: dwellings, 2021 edition incorporating 2023 amendments (PDF) read 3 November 2026
- Energy Saving Trust — boilers (secondary source) read 3 November 2026
Get a quote for a hot water cylinder
Tell us what heats your water now, where the cylinder sits and whether you want it replaced on its own or along with a new boiler. We reply by email.
What happens next
- Your details go to SEO-DONS LTD, the company behind Heating and Boiler Installation.
- We read what you have sent about the house and its heating, and reply by email.
- Asking for a quote costs nothing and leaves you free to say no.