England's rules
What the rules require now, and what changes on 24 March 2027
Fitting a gas boiler in England draws on gas safety law, the building regulations and the Approved Documents. Here is each rule in plain words, and what the 2026 edition of Approved Document L changes from 24 March 2027.
Last reviewed · facts read at source on 3 November 2026 · published by SEO-DONS LTD · sources
Who does the work
Gas work is for a business on the Gas Safe Register
Under regulation 3 of the Gas Safety (Installation and Use) Regulations 1998, employers may not let staff work on a gas fitting, and self-employed people may not do so themselves, unless the business belongs to the class of persons HSE designates: the Gas Safe Register. Falsely claiming membership is an offence in itself. Unlike the building rules below, this law reaches Wales and Scotland as well as England.
The register took over from CORGI on 1 April 2009 and covers natural gas and LPG. The back of each engineer's ID card lists the categories of work they are qualified for.
A plumber who is not registered may still fit water pipes and radiators, HSE says, but the boiler and its final water connection are for a registered engineer, and knowingly signing off unregistered work leaves both open to prosecution. For a whole new system, see central heating installation.
Sign-off
How a finished job is certified
Fitting a gas boiler counts as building work, and so does installing a heating or hot water system or the controls that go with it. Schedule 3 of the Building Regulations 2010 lets a business on the Gas Safe Register certify such work itself, so nothing goes to the council beforehand.
Within 30 days of completion, the installer gives whoever lives there a copy of the compliance certificate, and gives building control a notice or the certificate. Handover is covered on new boiler installation.
A firm outside every scheme cannot self-certify: the Planning Portal says the firm or the householder must notify the council in advance and pay a fee. That page's boiler efficiency figure is out of date, so go by the 92% in Approved Document L.
Rule by rule
Each rule, and whether 24 March 2027 changes it
Paragraph numbers in the middle column are from the 2021 edition of Approved Document L (with 2023 amendments); those on the right are from the 2026 edition.
| Rule | What it asks for now | From 24 March 2027 |
|---|---|---|
| Who may do gas work | A business on the Gas Safe Register (England, Wales and Scotland) | Gas safety law, not Approved Document L |
| Efficiency | 92% ErP or better for gas wet heating in an existing home (Table 6.2); SEDBUK 2009 78% natural gas or 80% LPG only in exceptional circumstances | 92% ErP kept, now Table 5.3 |
| A combi’s extra measure | One of four: flue gas heat recovery, weather or load compensation, or a smart thermostat with automation and optimisation (6.2) | Kept, now paragraph 5.9 |
| Time and temperature control, interlock | With any new gas or oil boiler fitted in an existing home (Boiler Plus; interlock at 5.25) | Kept: both editions carry Boiler Plus |
| Other controls | Thermostatic control in each room where feasible (5.20); separate timing for heating and hot water unless one controller does both (5.24); a thermostat on a replacement cylinder (5.26) | No change identified |
| Sizing | From a heat loss calculation; not significantly oversized (5.8) | Firmer: a whole-dwelling calculation, and the old boiler’s output “is not appropriate” as the basis (4.9) |
| Combi turn-down | Down to the typical heating load (5.9) | Down to the typical mid-season heating load (4.11) |
| New or fully replaced system | Designed for a 55°C flow or lower, or the lowest feasible (5.10) | Kept (4.10) |
| Cleaning and commissioning | Cleaned and flushed, inhibitor added, commissioned to BS 7593 (8.8) | No change identified |
| CO alarm and flue position | Alarm in the boiler’s room (3.43); minimum flue distances (Diagram 34) | Approved Document J, not L |
| Unvented cylinder | Notifiable work (3.40 to 3.42) | Approved Document G, not L |
Quoted before 24 March 2027, fitted after it?
The amending regulations (SI 2026/335) start on 24 March 2027, but building work notified before then and begun before 24 March 2028 may stay on the earlier rules. If you accept a quote before the changeover and the boiler goes in after it, ask which edition the job follows, and get the answer in writing.
What changes
Sizing from the house, not the old boiler
The current edition already asks for a heat loss calculation and warns against significant oversizing. The 2026 edition is blunter where only the boiler is replaced: a note to paragraph 4.9 says a whole-dwelling heat loss calculation is appropriate even then, and that basing the new boiler on the output of the one it replaces "is not appropriate".
Paragraph 4.11 also asks for a combi that can turn down to the typical mid-season heating load. If a quote states a kW output, ask how it was reached; for the radiator side, see radiators and flow temperature.
What stays
The standards that carry on unchanged
Gas wet heating in an existing home still needs 92% ErP, a new combi still needs one of the four extra measures, and a newly installed or fully replaced system is still designed for 55°C or lower.
The first two are Boiler Plus standards, introduced in England in April 2018, which also made time and temperature controls and a boiler interlock standard whenever a gas or oil boiler is replaced. A quote without them falls short under either edition; the combi options are compared under heating controls.
Around the boiler
The alarm, the flue, the cylinder and planning
Approved Document J asks for a carbon monoxide alarm in the room whenever a new or replacement fixed gas appliance, other than a cooking-only one, is installed in a home. It also fixes where a fanned-draught balanced flue may end, from 75 mm below a gutter to 1,500 mm vertically from another terminal on the same wall; see flues, condensate pipes and CO alarms.
Approved Document G makes fitting an unvented cylinder notifiable, and only someone in a scheme for that work, or holding a current skills card, should fit one; see hot water cylinders. For heating and hot water systems generally, GOV.UK lists APHC, BESCA, Blue Flame Certification, Certsure, the Gas Safe Register, HETAS, NAPIT and OFTEC as competent person schemes.
Planning permission is not normally needed for internal work, and an external flue is normally permitted development, with exceptions for listed buildings and some protected areas. To test a quote against these rules, use comparing heating quotes, or get a heating quote for your own house.
Questions about the rules in England
Does swapping a boiler for the same model still have to meet today’s rules?
Yes. Fitting a gas boiler is building work, so the new one is judged against the standards in force when it goes in: 92% ErP, the required controls, a cleaned and protected system and, on a combi, one of the four extra measures.
What counts as a hard water area for the scale rule?
Above 200 ppm of total hardness. Approved Document L uses that figure, measured as calcium carbonate, and in such areas the water feeding a combi’s hot water circuit should be treated against scale.
I live in Wales or Scotland. Does any of this apply?
The gas safety law does, so gas work there is also for a business on the Gas Safe Register. The Approved Documents described here are England’s; Wales and Scotland set their own building standards, which this site has not checked.
Is the compliance certificate proof that the work was done properly?
Not conclusive proof. The Building Regulations 2010 make it evidence that the work complies, but not conclusive evidence, so keep it with the commissioning record.
Where this page's facts come from
- legislation.gov.uk — Gas Safety (Installation and Use) Regulations 1998, regulation 3 read 3 November 2026
- HSE — the Gas Safe Register and the engineer ID card read 3 November 2026
- HSE — who can do gas work, and the limits of "wet work" read 3 November 2026
- legislation.gov.uk — Building Regulations 2010, Schedule 3 (self-certification) read 3 November 2026
- legislation.gov.uk — Building Regulations 2010, regulation 20 (compliance certificates) read 3 November 2026
- Planning Portal — boilers and heating: building regulations read 3 November 2026
- Planning Portal — boilers and heating: planning permission read 3 November 2026
- GOV.UK — Boiler Plus policy review (PDF) read 3 November 2026
- GOV.UK — Approved Document L, Volume 1: dwellings, 2021 edition incorporating 2023 amendments (PDF) read 3 November 2026
- GOV.UK — Approved Document L, 2026 edition (applies from 24 March 2027) read 3 November 2026
- legislation.gov.uk — The Building Regulations etc. (Amendment) (England) Regulations 2026 (SI 2026/335) read 3 November 2026
- GOV.UK — Approved Document J, 2022 amendments (PDF) read 3 November 2026
- GOV.UK — Approved Document G, with 2024 amendments (PDF) read 3 November 2026
- GOV.UK — competent person schemes: current schemes read 3 November 2026
Want a quote that meets the current rules?
Tell us what heats the house now, and whether you want the same type of boiler, a different type or a whole new system. We reply by email.
What happens next
- Your details go to SEO-DONS LTD, the company behind Heating and Boiler Installation.
- We read what you have sent about the house and its heating, and reply by email.
- Asking for a quote costs nothing and leaves you free to say no.